This feature is unavailable at the moment.

We apologize, but the feature you are trying to access is currently unavailable. We are aware of this issue and our team is working hard to resolve the matter.

Please check back in a few minutes. We apologize for the inconvenience.

- LoopNet Team

You must register your contact information to view secure information on this listing.
This Industrial Property is no longer advertised on LoopNet.co.uk.

6325 Morenci Trl
Indianapolis, IN 46268
IN02 Indianapolis Data Center · Industrial Property For Sale

PROPERTY FACTS

Property Type Industrial
Property Subtype
  • Office Telecom Hotel Data Hosting
Costar Property Class B
Total Plot Size 1.47 ac
Net Internal Area (NIA) 19,200 sq ft
No. Floors 1
Year Built/Renovated 1975/2024
Parking Allocation 2.1/1,000 sq ft
Eaves Height 20 ft
Use Class I-2-S

AMENITIES

  • 24 Hour Access
  • Air Conditioning

UTILITIES

  • Lighting
  • Water
  • Sewer
  • Heating

ABOUT 6325 MORENCI TRL , INDIANAPOLIS, IN 46268

Offering: 6325 Morenci Trail is located on the northwest corridor of Indianapolis, Just of I-465 at Georgetown and 62nd St. It is located approximately 10 miles from the heart of downtown Indianapolis, in a nondescript office/flex park away from any major highways, air traffic patterns or neighboring businesses that might present a risk. The building was originally constructed as a data center in 1975 with harden structure, twin T reinforced concrete, and 15’ ceilings. The 19,100 SF was completely remodeled in 2006/2007 into a state-of-the-art data center that is currently managed and maintained by the data center occupant since the remodel. The current data center space consists of three separate rooms – 2 are 660 sf and 1 is 5,000 sf. There is an additional 3,500 sf contiguous to the existing data center space that would easily be converted into future data center space. Facility • Construction Type: Twin T Concrete • Approx Raised Floor SF: 6,450 SF • Approx. Expandable Raised Floor SF: 3500 SF Floor Load: 1,600lb per SF • Onsite Temperature Controlled Storage • Roof: Concrete T’s with 4” foam insulation & EPDM rubberized membrane held down by a ballast (NEW installed 2017 with warranty) • Documented and Auditable Maintenance Program (All Equipment Under Maintenance Contract) • An Environmental Type II is on file and available for review. • 12’ Double Reinforced Concrete Structure • No Glass or Windows attached to the facility • Anti-Static Entry • Uninterruptible Power Supply (UPS): Four 225 kVA output UPS in 2N • PDU Section: Four 120 kVA 400 amp PDU’s in 2N, 2 more in larger area • Generators: 1 Caterpillar 750KW diesel, tested weekly • 2N Design for UPS & PDU • 2,000 Amp ATS between Utility and Generator Power Sources • Redundant Feeds for all Placed Equipment • Second transfer switch for a rental generator. • Third transfer switch in the operations center • A&B designed: transfer switches, UPS’s and PDU’s. UPS systems are Ethernet connected. • Four, 225 kVa UPS systems designed N+1; Four, 120 kVa PDU’s designed N+1 Fuel Tank • 5,000-gallon capacity (4,800 actual due to EPA fuel expansion requirements) • 50-gallon engine startup tank within the generator building • Omnimetrix tank monitoring system installed. For amount, expansion, water, debris, etc. Cooling Systems • Equipment rooms (3) have two (N+1) 30-ton, Emerson Liebert air-cooled systems each • The Downs UPS fenced area has two (N+1) 25-ton, Carrier air-cooled systems • The telecom entrance room has one Liebert 30-ton, split system (installed 2018) • The telecom room and vault have one, shared, ten-ton air-cooled Carrier system • The offices, warehouse, conference, and power rooms have several zoned rooftop units • The equipment rooms include Emerson Liebert systems HVAC controls • The rest of the building has thermostat controls. Some are Ethernet connected. • 2N Design for CRAC and In-Row XD systems • Dust Control System Installed • Hot Aisle, Cold Aisle Design Telecom Service • East-West Armored Conduit Entrance • North-South Armored Conduit Entrance • Carriers: AT&T, Zayo/Cogent, Centurylink: the Level3, Quest, and CenturyLink circuits into the building and has dual entrance optical fiber • Card or fob system for every exterior and interior major door. • Secured Best Lock and Falcon keyed doors. • Front door hand scanning system • Twenty-seven exterior and interior color cameras to a hard drive and projection systems • 7x24 external monitoring company capable • Exterior fenced-in area. • Broken glass window security • Secured engine/generator building • Front door man trap with talkbox and secured door opening button • Active Glass Breaks on all Administrative Areas • Frosted, mirrored man-trap entry • Onsite, Climate Controlled Safe Fire Systems • Dry pipe, wet pipe, and clean agent suppression systems • Each clean agent room has its own control and monitoring panels • Room clean agent control panels are tied to a master control panel • Front exterior includes a fire department monitoring panel and building keys Knox Box • Two backflows tested fire water entrances • Equipment room or general use fire extinguishers installed throughout the building • Battery-powered lighting systems throughout the building • Main control panel has 7x24 external monitoring service capabilities • Dry Pipe System • Conference Room • HD Television • HD Video Projection • VCR/DVD • 7.1 Stereo • Overhead Projection • Dedicated Ethernet Ports for Direct Internet • Secured Shower Facilities • Meets all ADA regulations

PROPERTY TAXES

PROPERTY TAXES

Parcel Number
49-03-31-117-019.000-600
Land Assessment
£156,858
Improvements Assessment
£583,866
Total Assessment
£740,724
  • Listing ID: 15977235

  • Date on Market: 07/05/2019

  • Last Updated:

  • Address: 6325 Morenci Trl, Indianapolis, IN 46268

Link copied
Your LoopNet account has been created!

Please Share Your Feedback

We welcome any feedback on how we can improve LoopNet to better serve your needs.
X
{{ getErrorText(feedbackForm.starRating, "rating") }}
255 character limit ({{ remainingChars() }} charactercharacters remainingover)
{{ getErrorText(feedbackForm.msg, "rating") }}
{{ getErrorText(feedbackForm.fname, "first name") }}
{{ getErrorText(feedbackForm.lname, "last name") }}
{{ getErrorText(feedbackForm.phone, "phone number") }}
{{ getErrorText(feedbackForm.phonex, "phone extension") }}
{{ getErrorText(feedbackForm.email, "email address") }}